FREE shipping to on qualifying orders when you spend or more, processed by Ossila BV. All prices ex. VAT. Qualifying orders ship free worldwide! Fast, secure, and backed by the Ossila guarantee. It looks like you are visiting from , click to shop in or change country. Orders to the EU are processed by our EU office.

It looks like you are using an unsupported browser. You can still place orders by emailing us on info@ossila.com, but you may experience issues browsing our website. Please consider upgrading to a modern browser for better security and an improved browsing experience.


Product Code L2002A3-US
Price $3,240 ex. VAT

Ultra-Clean Surfaces in Minutes

Produce near-atomically clean surfaces without causing damage to your sample


Overview | Specifications | Features | Gallery | In the Box | Resources and Support


Within minutes, the Ossila UV Ozone Cleaner is capable of removing contamination from the surface of substrates and samples. Using a high-power UV light source to generate ozone and break down organic surface contaminants, you can produce near-atomically clean surfaces without causing any damage to your sample. Volatile compounds created from surface contaminants will quickly evaporate, leaving the sample ready for the next part of your experiment.

The cleaning area has a diameter of 153 mm, providing plenty of space to clean multiple samples at once, microscope slides, or even petri dishes. During cleaning, your delicate samples are protected from overheating as the integrated software monitors the internal temperature and provides readings for the tray, lamp, and electronics.

An essential addition to any lab, our UV ozone cleaner is able to treat a wide range of materials for a number of different applications.

Lightweight Body

Lightweight Body

Easily moved

High intensity UV lamp

High Intensity UV Lamp

Emission at 185 nm and 254 nm

Safe

Safe Design

Thermal cutoff and safety interlock

Two-Year Warranty

Two-Year Warranty

Buy with confidence

Specifications


UV Intensity 15 mW·cm-2 at 185 nm
UV Emission 185 nm and 254 nm LED
Lamp Lifetime >2000 hours
Cleaning Area 153 mm diameter
Safety Features Temperature regulation, thermal cutoff, and drawer interlock

UV Ozone Cleaner Features


UV Ozone Mercury Vapour Discharge Lamp

High Intensity UV Lamp

Housing a series of high intensity, low pressure synthetic quartz mercury vapour discharge lamps. By utilizing the emission at 185 nm and 254 nm, ozone is generated. The high intensity output gives results quickly and facilitates a large cleaning area.

UV Ozone Cleaner Illumination Area

Large Cleaning Area

The tray can accommodate wafers up to 153 mm in diameter and 12mm in thickness for a wide array of samples, including:

Check MarkMicroscope slides
Check MarkDiced substrates
Check MarkPetri dishes
Check MarkAFM tips
Simple To Use UV Ozone Cleaner

Simple to Use Interface

The bright LCD display and tactile keypad provide a simple interface.

The integrated software continuously monitors the temperature inside the system and gives readings for the tray, UV lamp, and electronics. This makes it easy to make sure that delicate samples do not overheat.

Ossila UV Ozone Cleaner designed for safety

Designed with Safety in Mind

Our system adheres to BS EN 61010-1:2010 standards alongside EMC, Low Voltage, and RoHS CE directives. Smart safety features include an integrated safety interlock which keeps the lamp off while the tray is open. Plus, a thermal cutoff is triggered if the temperature detected by any of the internal sensors is too high.

Ossila UV Ozone Cleaner designed for safety

UV Lamp Replacement Service

Every UV bulb has a finite lifetime and lower bulb intensity means increased cleaning times. When this happens, we offer a UV Lamp Replacement Service. We will replace your bulbs, fully test all components, ensuring they meet all safety standards, and safely dispose of your old bulbs. This ensures minimal downtime and maximum lifetime for your equipment.


UV Lamp Replacement Service


For safe and successful bulb replacement, simply place an order for a new bulb and send the UV Ozone Cleaner back to us at Ossila. Once it arrives in house, we can replace the bulb and have it ready for return within 48 hours. Within this service, we will:

  • Replace the UV bulb
  • Fully test all components to ensure they are working as intended
  • Check that all components meet the required safety standard
  • Safely dispose of the old bulb

We recommend bulb replacement is undertaken by us rather than installing the bulb yourself as the system operates at high voltage. Incorrect assembly of the unit after bulb replacement may result in serious or fatal injury. Please feel free to contact us if you have any questions about this.

In the Box


  • UV Ozone Cleaner
  • Power supply

Resources and Support


Ossila UV Ozone Cleaner User Manual Which UV Ozone Cleaner Features do I Need?

It is always important to assess the necessity and applicability of additional features in your experimental set up. The Ossila UV Ozone Cleaner is built with simplicity and efficacy in mind.

Read more...
Return to the top