Software and Drivers
Equipment |
Software |
Source Measure Unit |
|
Solar Simulator |
|
Solar Cell I-V Test System |
|
LED Measurement System |
|
OLED Lifetime System |
|
Four-Point Probe System |
|
Contact Angle Goniometer |
|
Potentiostat |
|
Optical Spectrometer |
|
Linear Stage |
|
All |
SMU Front Panel
This is the latest version of the SMU Front Panel for the Source Measure Unit.
Software | Version | File Size | Download |
Ossila SMU Front Panel | 2.0.2 | 67 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 200 MB |
Connectivity | USB 2.0 Ethernet |
New Features
Front Panel
- SMU channels now disable when the voltage or current limit are exceeded.
- "Overcurrent" is displayed on a SMU channel when the voltage or current limit is exceeded.
Data Plot
- The number of data points displayed by the plots can now be manually set up to 9999.
- Data is no longer added to the plot's data storage when plotting is paused.
- Grid lines can now be turned on or off.
Data Logging
The Data Logging feature has been completely redesigned:
- Logging is now switchable instead of occurring only when a button is pressed, allowing data to be continuously logged.
- The time between logging data points and a total logging duration can be set.
- Data can be saved to file as it is logged.
IV Measurement
- Individual measurements can now be saved and deleted.
- Measurements can now be given custom labels by the user.
Bug Fixes
- Fixed a bug which prevented channels from switching on when another enabled channel was using the highest sampling rate.
I-V Curve
This is the latest version of the current-voltage measurement software for the Source Measure Unit.
Software | Version | File Size | Download |
Ossila I-V Curve | 4.0.4 | 61 MB | Software Manual |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 172 MB |
Monitor Resolution | 1680 x 1050 |
Connectivity | USB 2.0 Ethernet (requires DHCP) |
Updates
- Updated license information.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 4.0.1.
Solar Simulator Console
This is the latest version of the control software for the Solar Simulator.
Software | Version | File Size | Download |
Ossila Solar Simulator Console | 1.5.1 | 58 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 152 MB |
Monitor Resolution | 1440 x 960 |
Connectivity | USB 2.0 |
Updates
- Updated license information.
Solar Cell I-V
This is the latest version of the measurement software for the Solar Cell I-V Test System.
Please note, this version of the software is incompatible with automated versions of the system with product codes ending in 1 or 2 (e.g., T2003A2), purchased before August 2022. For these systems, use the Solar Cell I-V (Legacy) software below.
Software | Version | File Size | Download |
Ossila Solar Cell I-V | 2.2.4 | 79 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 278 MB |
Monitor Resolution | 1680 x 1050 |
Connectivity | USB 2.0 Ethernet (requires DHCP) |
Updates
- Updated license information.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 2.0.0.
Solar Cell I-V (Legacy)
This is the measurement software for Automated Solar Cell I-V Test Systems with product codes ending in 1 or 2 (e.g., T2003A2), purchased before August 2022.
Software | Version | File Size< / strong> | Download |
Ossila Solar Cell I-V (Legacy) | 1.9.1 | 79 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 268 MB |
Monitor Resolution | 1680 x 1050 |
Connectivity | USB 2.0 Ethernet (requires DHCP) |
New Features
Updates
- Updated license information.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 1.7.0.
LED IVL
This is the latest version of the measurement software for the LED Measurement System. Please note, this software is NOT compatible with the OLED Lifetime System.
Software | Version | File Size | Download |
Ossila LED IVL | 3.0.2 | 62 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 172 MB |
Monitor Resolution | 1440 x 960 |
Connectivity | USB 2.0 Ethernet (requires DHCP) |
Updates
- The current range now changes to the 200 mA range when holding multiple pixels between measurements.
- Updated license information.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 3.0.0.
LED I-V (Legacy)
This is the latest version of the measurement software for the OLED Lifetime System.
Software | Version | File Size | Download |
Ossila LED I-V | 2.2.2 | 42.4 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 268 MB |
Monitor Resolution | 1440 x 960 |
Connectivity | USB 2.0 Ethernet (requires DHCP) |
Updates
- Updated license information.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 2.2.1.4.
Sheet Resistance Lite
This is the latest version of the sheet resistance measurement software for the Ossila Four-Point Probe.
Software | Version | File Size | Download |
Ossila Sheet Resistance Lite | 1.0.9 | 80 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 269 MB |
Monitor Resolution | 1440 x 900 |
Connectivity | USB 2.0 Ethernet (requires DHCP) |
Updates
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 1.0.4.
Bug Fixes
- Fixed a bug which caused the connected system to have to be reset before it could be used again after performing a sheet resistance measurement.
Sheet Resistance
This is the old version of the sheet resistance measurement software for the Ossila Four-Point Probe.
Software | Version | File Size | Download |
Ossila Sheet Resistance | 2.1.0 | 78 MB | Software Manual |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 267 MB |
Monitor Resolution | 1440 x 900 |
Connectivity | USB 2.0 Ethernet (requires DHCP) |
Source code for this software can be downloaded from here: Ossila Sheet Resistance source.
Updates
- Added compatibility with the Four-Point Probe Plus.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 2.0.8.
Contact Angle
This is the latest version of the measurement software for the Ossila Contact Angle Goniometer.
Software | Version | File Size | Download |
Ossila Contact Angle | 4.2.1 | 86 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Quad Core 2.5 GHz |
RAM | 8 GB |
Available Drive Space | 300 MB |
Monitor Resolution | 1920 x 1080 |
Connectivity | USB 2.0 |
Updates
- Updated license information.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 4.1.5.
Electrochemistry
This is the latest version of the electrochemistry measurement software for the Ossila Potentiostat.
Software | Version | File Size | Download |
Ossila Electrochemistry | 1.4.1 | 79 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2.5 GHz |
RAM | 4 GB |
Available Drive Space | 268 MB |
Monitor Resolution | 1280 x 960 |
Connectivity | USB 2.0 |
Updates
- Updated license information.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 1.2.0.
Spectroscopy
This is the latest version of the Ossila Optical Spectrometer Software for use with the USB Spectrometer.
Software | Version | File Size | Download |
Ossila Spectroscopy | 1.3.1 | 93 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 306 MB |
Connectivity | USB 2.0 |
Updates
- Updated license information.
- 32-bit operating systems are no longer supported, for 32-bit operating systems use version 1.1.2.
Motion Control
This is the latest version of the Ossila Motion Control Console for use with the Linear Stage.
Software | Version | File Size | Download |
Ossila Motion Control Console | 1.0.1 | 58 MB |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 152 MB |
Connectivity | USB-C |
Updates
- Updated license information.
Firmware Updater
This is the latest version of the Ossila Firmware Updater Software which can be used to install firmware updates for Ossila equipment (except the Optical Spectrometer).
Software | Version | File Size | Download |
Firmware Updater | 1.1.1 | 61 MB | Software Manual |
Minimum System Requirements
Operating System | Windows 10 or 11 (64-bit) |
CPU | Dual Core 2 GHz |
RAM | 4 GB |
Available Drive Space | 161 MB |
Connectivity | USB 2.0 |
Bug Fixes
- Fixed a bug where searching for devices would cancel if it encountered an already opened serial port.
Other Files
Source Measure Unit USB Drivers
These drivers are required use USB connectivity with our electrical test and measurement systems and the Source Measure Unit (Xtralien X100 and X200). The file contains both the 32-bit and 64-bit installers. For instructions on how to install the drivers, please see our installation guide.
Software | Version | File Size | Download |
Source Measure Unit USB Drivers | 2.1.00 | 800 kB |
Source Measure Unit LabVIEW Library (Legacy)
This is a collection of VIs for using the Source Measure Unit - X200 with LabVIEW 2015.
These files are no longer supported or updated. To control the Source Measure Unit with LabVIEW, serial and string commands can be used.
Software | Version | File Size | Download |
Source Measure Unit LabVIEW Library | 2.1.0.0 | 440 kB |
End-User License Agreement
Below are the end-user license agreements for the software on this page:
- Ossila SMU Front Panel EULA
- Ossila I-V Curve EULA
- Ossila Solar Simulator Console EULA
- Ossila Solar Cell I-V EULA
- Ossila Solar Cell I-V (Legacy) EULA
- Ossila LED IVL EULA
- Ossila LED I-V (Legacy) EULA
- Ossila Sheet Resistance Lite EULA
- Ossila Sheet Resistance EULA
- Ossila Contact Angle EULA
- Ossila Electrochemistry EULA
- Ossila Spectroscopy EULA
- Ossila Motion Control Console EULA
- Ossila Firmware Updater EULA
Notices
End-user software has been developed using Qt5 under LGPLv3 (Ossila SMU Front Panel, Ossila Solar Simulator Console, Ossila Motion Control Console, and Ossila Firmware Updater excepted). Qt is copyright (c) 2024 The Qt Company. You can download copies of the Qt source libraries used from the following link: Qt5 source files.
To use your own Qt5 library, simply replace the dynamic link libraries (.dll files) found in the "PyQt5" folder in the installed software directory, for more information please contact us.
You can view copyright and license information of third-party software used in Ossila software here: third-party notices.